Uniscope Host Port Parameters
409
Uniscope Host
Port Parameters
(a) Host Name: up to 17 ASCII characters, null string
(b) Alternate Host Name: up to 17 ASCII characters, null string
(c) Poll Timeout: 1 to 65535 (in 10-millisecond increments), 6000
(d) Input Timeout: 1 to 65535 (in 10-millisecond increments), 300
(e) Link Speed:Async: 300, 1200, 2400, 4800, 9600, 192000, or 38400 bps,
Sync: 1200, 2400, 4800, 7200, 9600, 12000, 16800, 14400, 16800, 19200, 24000, 28800,
38400, 56000, or 64000 bps
(f) Character Length: 7 or 8 bits
(g) Parity: None, Even, or Odd (Even for an asynchronous Link Interface; Odd for a synchronous Link Interface.)
(h) Link Interface: Async or Sync
(i) Link Termination: DCE or DTE
(j) No. of Trailing PADs: 0 to 255, 2
(k) Turnaround: 0 to 10 (in 10-millisecond increments)
(l) RTS/CTS Control: Dynamic, Fixed On, or Floating
(m) No. Char before Tx: 1 to 4096
(n) Max Messages Queued: 1 to 255, 3
(o) End-to-End Flow Control: Yes or No
(p) Protocol Conversion: Yes or No
(q) Ack Passing: Yes or No
(r) Address List
(a) RID Address: one displayable character, null string
(b) SID List
(a) SID Address: one displayable ASCII character, null string
(b) Connect Name: up to 17 ASCII characters, null string
(c) Options
Timeout If Offline (Y or N) ?
Flush Data If Offline (Y or N) ?
Automatic Connection while Select (Y or N) ?
Automatic Connection while Link Active (Y or N) ?
(d) Clear
Defaults are underlined.