Upline Controller
When set to Y (yes), the unit knows another TXPORT unit is connected upstream
and issues a Disconnect command to the upstream TXPORT device when a local
station goes offline. If any stations on this port use transmission numbers, set this
parameter to N. The selections are Y (yes) and N (no).
Host Name
Each Poll/Select Host port must be assigned a name. This may be any combination
of up to 17 alphanumeric characters. A space, or the end of the field, delimits the
entry. This name is used in the terminal’s Default Host field. The default name is
UNISYS.
Backup Host Name
When declared off-line, the port transfers all current station connections to the host
named in this field. By default, this field is (blank).
Unisys Poll/Select
Host Addresses
Each of these parameters is described in the following paragraphs.
Line Module
This field indicates the line module number of the port being displayed. Entering a
different line module number and pressing F10 transfers the screen to the same
port on the new line module.
TXPORT INTELLINET Configuration Program
Configuration 1000
Host Port Station Parameters
Line Module [1 ] Port [1] Description
Host Group Auto Connect Options XN #
Address Address Station Name ABCDEFGHIJKLMNOP Type
Address:
F1=Hlp F2=Mod F3=Add F4=List F5=Clr F6=DelAll F7=Copy F8=Jmp F9=Prev F10=Next
Figure 5-5 Unisys Poll/Select Addresses