Configuration / Operation

95

Unisys

Poll/Select

Host

Each of these parameters is described in the following paragraphs.

Defaults are shown underlined.

Line Module

This field indicates the line module number of the port being displayed. Entering a
different line module number and pressing F10 transfers the screen to the same
port on the new line module.

Port

The port field indicates the number of the displayed port. A different port may be
selected by entering its number in this field and pressing F10.

Description

This is a free-form field intended to describe the location or department this port
services.

Copy Port Parameters

The three fields on this line work together to allow copying an existing port
configuration to the current port.

Configuration.

Enter the configuration number where the stations to be copied

reside.

Module.

This parameter represents the line module number in the source unit.

Port.

Enter the port number where the source stations reside.

TXPORT INTELLINET Configuration Program

Configuration 1 Burroghs

Unisys Poll/Select Terminal Port Parameters

Line Module [01] Port [1] Description [Poll/Select Host ]

Copy Port Parameters from Configuration [ ] Module [ ] Port [ ]

Baud Rate [19200] Bits per Character (7/8) [7]

Parity (O/E/N) [E] Message Buffer [4096]

Interface (S/A/T/V) [T]

Termination (DCE/DTE) (9200 only) [DCE]

Trailing Pads (0/1/2) [0]

Turnaround Delay (ms) [ 10]

RTS/CTS Control (O/D/F) [F]

Messages per Group Poll [N]

Offline Timeout (sec) [ 500]

Upline Controller (Y/N) [N]

Host Name [ ]

Backup Host Name [ ]

ESC=Main Menu F1=Help F5=Clear F7=Redisplay F8=Jump F9=Previous F10=Next

Figure 5-4 Unisys Poll/Select Host