216
C
HAPTER
12: F
RAME
R
ELAY
P
ROTOCOL
Figure 12-7 shows the endpoint list for unit 001’s frame relay port which connects
to unit 002. Note that the DLCI for this connection does not have to be the same
as the above port. Also note that additional DLCIs could be defined that are not
transparent to carry other traffic such as LAN or legacy data.
Figure 12-8 displays the endpoint list corresponding to unit 002’s frame relay port
which is connected to unit 001.
TXPORT INTELLINET Configuration Program
Configuration 1000
Frame Relay / TXPORT Multidrop List Endpoint
Line Module [1 ] Port [2] Description
Copy Access List from Configuration [ ] Module [ ] Port [ ]
Address/ Alternate Default Options
DLCI Endpoint Endpoint Connect ABCDEFGHIJKLMNOP
0025 REMOTE-FRAME YNNNNNNNNNNNNNNN
F1=Hlp F2=Mod F3=Add F4=List F5=Clr F6=DelAll F7=Copy F8=Jmp F9=Prev F10=Next
Figure 12-7 Endpoint List for Unit 001 Connected to Unit 002
TXPORT INTELLINET Configuration Program
Configuration 1000
Frame Relay / TXPORT Multidrop List Endpoint
Line Module [1 ] Port [2] Description
Copy Access List from Configuration [ ] Module [ ] Port [ ]
Address/ Alternate Default Options
DLCI Endpoint Endpoint Connect ABCDEFGHIJKLMNOP
0025 LOCAL-FRAME REMOTE-FRAME YNNNNNNNNNNNNNNN
F1=Hlp F2=Mod F3=Add F4=List F5=Clr F6=DelAll F7=Copy F8=Jmp F9=Prev F10=Next
Figure 12-8 Endpoint List for Unit 002 connected to Unit 001