Bisync host port parameters – Verilink 9000 Series (34-00271) Product Manual User Manual
Page 427

Bisync Host Port Parameters
405
Bisync Host Port
Parameters
(a) Host Name: up to 17 ASCII characters, null string
(b) Alternate Host Name: up to 17 ASCII characters, null string
(c) Host Timeout: 1 to 65535 (in 10-millisecond increments), 3000
(d) Response Timeout: 100 to 6500 (in 10-millisecond increments), 300
(e) Link Speed:1200, 2400, 4800, 7200, 9600, 12000, 14400, 16800, 19200, 24000, 28800, or 38400 bps
(f) Link Interface: V35 or RS232
(g) Link Termination: DCE or DTE
(h) Turnaround: 0 to 10 (in 10-millisecond increments)
(i) RTS/CTS Control: Dynamic, Fixed On, or Floating
(j) No. Char before Tx: 1 to 4096
(k) Messages per Group Poll: 1 to 255, 4
(l) Max Messages Queued: 1 to 255, 4
(m) End-to-End Flow Control: Yes or No
(n) Protocol Conversion: Yes or No
(o) Address List
(a) CU Address: 00
16
to FF
16
(b) CU Type: RMBCS, 3274, or 3275
(c) SID List
(a) Device Address:
(b) Connect Address: two displayable ASCII characters, (CU
Address/Device Address combination)
(c) Connect Name: up to 17 ASCII characters, null string
(d) Options
Timeout If Offline (Y or N) ?
Flush Data If Offline (Y or N) ?
Automatic Connection while Select (Y or N) ?
Automatic Connection while Link Active (Y or N) ?
Flush Output If Offline (Y or N) ?
Defaults are underlined.