Configuration / Operation
123
Bisync
Host Port
Parameters
Figure 7-4 shows a Bisync Terminal Port parameters screen.
Defaults are shown underlined.
Line Module
This field indicates the line module number of the port currently being displayed.
Entering a different line module number and pressing F10 will transfer the user to
the same port on the new line module.
Port
The port field indicates the number of the port currently being displayed. A
different port may be selected by entering it's number here and pressing F10.
Description
This is a free form field intended to describe the location or department this port
services.
Copy Port Parameters
The three fields on this line work together to allow copying an existing port
configuration to the current port.
Configuration.
The number of the source configuration to copy from is entered in
this field. This can be any existing configuration, current or otherwise.
Line Module.
Enter the line module number of the port that is to be copied.
Port.
The number of the source port to be copied from is entered here.
Phoenix Data Communications INTELLINET Configuration Program
Configuration 1000
Bisync Host Port Parameters
Line Module [01] Port [4] Description [ ]
Copy Port Parameters from Configuration [ ] Module [ ] Port [ ]
Baud Rate [ 9600] Bits per Character (7/8) [8]
Parity (O/E/N) [N] Message Buffer [4096]
Interface (S/V) [S] Offline Timeout (sec) [ 30]
Termination (DCE/DTE) (9200 only) [DCE] Host Response Timeout (ms) [ 3000]
Trailing Pads (0/1/2) [1] Maximum Messages Queued [ 4]
Turnaround Delay (ms) [ 10] Messages per Group Poll [ 8]
RTS/CTS Control (O/D/F) [D] Backup Host Name [ ]
Host Name [ ] End to End Protocol Conversion [N]
End to End Flow Control [Y]
ESC=Main Menu F1=Help F5=Clear F7=Redisplay F8=Jump F9=Previous F10=Next
Figure 7-4 Bisync Host Parameters Screen
✍