Page 209: Configuration / operation

background image

Configuration / Operation

187

Configuration
/ Operation

Data Link

Protocol

Parameters

The DLP Port Parameters menu screen is used to define a port on the
communications platform that communicates with other devices supporting SDLC,
LAPB or any other BOP protocol. Figure 11-2 is an example of the Data Link
Protocol Parameters screen

These parameters are described in the following paragraphs.

Defaults are shown underlined.

Line Module

This field indicates the line module number of the displayed port. Entering a
different line module number and pressing F10 transfers the program to the same
port on the new line module.

Port

The port field indicates the number of the displayed port. A different port may be
selected by entering its number here and pressing F10.

Description

This is a free-form field intended to describe the location or department this port
services.

TXPORT INTELLINET Configuration Program

Configuration 1000

Data Link Protocol Parameters

Line Module [01] Port [4] Description [ ]

Copy Port Parameters from Configuration [ ] Module [ ] Port [ ]

Link speed [ 9600]

Link interface (R/V) [R]

Link termination (DCE/DTE) [DCE]

RTS/CTS control (D/O/F) [D]

Link active (B/S/N) [B]

NRZI (NRZ/NRZI) [ NRZ]

Data link type (T/S/L) [T]

ESC=Main Menu F1=Help F5=Clear F7=Redisplay F8=Jump F9=Previous F10=Next

Figure 11-2 Data Link Protocol Parameters Screen