NMCS Screens
321
IPX CIRCUIT
Parameters
To add or modify an IPX circuit from the main IPX Circuit menu, press F3 or F2
and Figure 19-4 appears. To list all configured IPX circuits, press F4.
Defaults are shown underlined.
Line Module
This field indicates the line module number of the port currently displayed.
Entering a different line module number and pressing F10 transfers the screen to
the same port on the new line module
Circuit Number
This number, ranging from 1 to 255, is assigned automatically by the system and
cannot be changed manually. Circuit number 1 is reserved for the LAN interface,
and all others are assigned to WAN interface.
Enable This Circuit
Setting this parameter to No disables a circuit without deleting its record in the
Router Configuration menu. It is also useful when testing an installation. By
default the circuit is enabled, that is, set to Yes.
IPX Network Address
The IPX Network Address must be configured. This is a 32-bit value. It represents
the IPX address of the circuit being defined. Hexadecimal notation is used here. A
valid example is 12345678.
TXPORT INTELLINET Configuration Program
Configuration
Add IPX Circuit
Line Module
Circuit number [ ] Enable this circuit [Y]
IPX Network Address [ ] Maximum Transmit Unit Size [1600]
Interface speed (bps) [ 56000] Propagation Delay (ms) [ 10]
Enable RIP/SAP [Y] Enable NLSP [Y]
Filter Type 20 Packet [Y]
Type of Circuit (WAN/LAN) [WAN] Encapsulation type (WAN) [PROP]
Frame Type (LAN) [ ] Circuit name [ ]
Circ. connect name [ ]
DLCI Number (WAN) [ ]
Enable IPXWAN2 (WAN) [N]
RIP/SAP Parameters
RIP Periodic Interval (s) [ 60] RIP Age Multiplier [ 3]
Maximum RIP Packet Size [ 512] SAP Periodic Interval (s) [ 60]
SAP Age Multiplier [ 3] Maximum SAP Packet Size [ 512]
F1=Hlp F2=Mod F3=Add F4=List F5=Clr F6=DelAll F7=Copy F8=Jmp F9=Prev F10=Next