beautypg.com

Discovering hp storageworks xp arrays, Discovering, Hp storageworks xp arrays – HP Storage Essentials Enterprise Edition Software User Manual

Page 96: Discovering hp storageworks, Xp arrays, Viewing or changing the, Community string in command view eva 6.x, Community string in command view eva 7.x, Configuring event and host, Notification in command view eva

background image

Discovering Switches, Storage Systems, NAS Devices, and Tape Libraries

58

Viewing or Changing the Community String in Command View EVA 6.x

To view or change the community string:

1.

Open the c:\hsvmafiles\nsaserver.ini file in a text editor on the Command View EVA

server.

2.

Find the line Authority=Public
This example shows the Command View EVA 6.x default: Public.

3.

Change the value to the desired community string. For example, if you want to change the

community string to public, enter Authority=public

4.

Restart the service for Command View EVA.

Viewing or Changing the Community String in Command View EVA 7.x

To view or change the community string:

1.

Open the C:\Program Files\Hewlett-Packard\Sanworks\Element Manager for
StorageWorks HSV\config\cveva.cfg

file in a text editor on the Command View EVA

server.

2.

Find the following command lines:

# Authority. Default = Public

authority Public

3.

Change the community string to the desired value. For example, if you want to change the

community string to public, enter authority public

4.

Restart the service for Command View EVA.

Configuring event and host notification in Command View EVA

See the HP StorageWorks Command View EVA user guide for instructions on configuring Command

View EVA event notification. The Command View EVA documentation is available at

http://www.hp.com/support/manuals

.

Discovering HP StorageWorks XP Arrays

You can discover HP StorageWorks XP Arrays by using the following methods:

Discovering HP XP Arrays by Using Command View XP and SMI-S

, page 59

Discovering HP XP Arrays by Using Command View XP Advanced Edition

, page 59

Discovering HP XP Arrays by using the built-in XP Provider

, page 59

This manual is related to the following products: