45

The management server excludes the switches with the following WWNs: 1000080088A07024

and 1000080088A0D0B6
If the cimom.mcdata.exclude property is not modified, the management server discovers and

obtains details from all McDATA and Connectrix switches.

IMPORTANT:

The IP addresses of excluded elements appear in the discovery (Tools > Storage

Essentials > Home > Discovery > Setup), topology (Tools > Storage Essentials > Home > Discovery

> Topology), and Discovery Data Collection (Options > Storage Essentials > Discovery > Run

Discovery Data Collection), lists. The management server does not display additional information

about excluded elements in the user interface. The management server, however, does mention in

the logs (Tools > Storage Essentials > Home > Discovery > View Logs) that a provider instance has

been created for an excluded element. You can ignore this log message.

To modify the cimom.mcdata.exclude property:

1.

Select Options > Storage Essentials > Manage Product Health, and then click Advanced in the

Disk Space tree.

2.

Click Show Default Properties at the bottom of the page.

3.

Copy the cimom.mcdata.exclude property.

4.

Click Close to return to the Advanced page.

5.

Paste the copied text into the Custom Properties box.

6.

Make your changes to the text in the Custom Properties box. Remove the pound (#) symbol in

front of the property to make sure it is not commented out.

7.

Add the WWNs corresponding to the switches you want to exclude from discovery. Separate

additional WWNs with a comma, as shown by the following example:
cimom.mcdata.exclude=1000080088A07024,1000080088A0D0B6
where 1000080088A07024 and 1000080088A0D0B6 are the WWNs for McDATA and

Connectrix switches.

8.

When you are done, click Save.

Managing McDATA and EMC Connectrix Switches

Whenever you add, remove or replace McDATA or EMC Connectrix switches in an

already-discovered service processor, you must make the management server aware of those

changes by performing Discovery Data Collection to obtain information about the new switches

from the service processor. For more information about adding switches, see,

Adding McDATA and

EMC Connectrix Switches

” on page 46.

When you remove switches from the service processor, you must remove them from the management

server. For more information about removing switches, see

Removing McDATA and EMC

Connectrix Switches

” on page 46.

When you replace McDATA or EMC Connectrix switches, you add and remove the switches as

described previously. For more information, see ”

Replacing McDATA and EMC Connectrix

Switches

” on page 46.