Troubleshooting

724

SGI IRIX host

CXFS file

systems

The management server can only monitor CXFS file systems

from the host generating the input/output. For example,

assume the elements are part of a CXFS file system. When you

generate input/output into the metadata server into /folder,

only the metadata server is able to monitor the file system. For

example, assume the metadata server generates 100 KB write,

the management server displays 0 KB write for /folder on

the metadata client.
See

About the Data from CXFS File Systems

” on page 327 for

more information.

Solaris host

Sun SAN

Foundation

Suite driver

(Leadville

driver)

The bindings page reports a SCSI number that comes from the

HBAAPI. This number cannot be seen by the user. For example

SCSI target 267008 does not correlate to anything.

Solaris host

HDLM

If you sync the Solaris host by itself without the switches and

storage, the storage volume page reports all drive types as

local.
Once you discover the host with the switches and storage, it

reports its drives as being external. It reports the same result

with Active-Active and Active-Standby.

Solaris host

HDLM

Solaris HDLM disks cannot be monitored. If you try monitoring

them, the management server displays a message saying

“data is late or an error occurred.”

Solaris host

HDLM

If you do a Discovery Data Collection for the host by itself, on

the bindings page, the controller number begins with c-1, for

example, c-1t0d58.
Perform Discovery Data Collection on the host with storage and

switches. The controller numbers are displayed correctly.