beautypg.com

Community string requirements, Obtaining snmp traps from command view – HP Storage Essentials Enterprise Edition Software User Manual

Page 95

background image

HP Storage Essentials SRM 6.0 User Guide

57

Indications for display in its Event Manager. HP Storage Essentials then forwards the events to HP

SIM's event console.

Community String Requirements

The default community string for Command View EVA 6.x is Public and the default community

string for HP Storage Essentials is public. The community strings must be a case-sensitive

match, so if you are using the default values in HP Storage Essentials and Command View EVA

6.x, you must change the community strings to a case-sensitive match.

If you are using the default community strings for Command View EVA 7.x and HP Storage

Essentials, no changes to the community strings are needed. If you change the community strings

to non-default values, then they must be a case-sensitive match.

CAUTION:

Other applications (such as HP SIM) may be using the default community strings

to communicate with Command View EVA. If you change the community string in Command

View EVA, you might break Command View EVA’s connection to other applications. If a

change is needed, we recommend changing the community string in Storage Essentials to

match the string in Command View EVA.

Obtaining SNMP traps from Command View

To obtain SNMP traps from Command View EVA:

1.

Verify that the community strings follow the rules in ”

Community String Requirements

” on

page 57. For information on viewing or changing community strings, see

Viewing or Changing

the Community String in HP Storage Essentials

” on page 57,

Viewing or Changing the

Community String in Command View EVA 6.x

” on page 58, or ”

Viewing or Changing the

Community String in Command View EVA 7.x

” on page 58.

2.

Configure event and host notification. For instructions, see ”

Configuring event and host

notification in Command View EVA

” on page 58.

Viewing or Changing the Community String in HP Storage Essentials

To view or change the community string:

1.

Select Options > Storage Essentials > Manage Product Health.

2.

Click Advanced in the Disk Space tree.

3.

Click Show Default Properties at the bottom of the page.

4.

Copy the cimom.snmpTrapListenerCommunityString variable.

The management server uses the value that is listed last, so be sure to search to the end of the

page to locate the latest build.

5.

Click Close to return to the Advanced page.

6.

Paste the copied text into the Custom Properties box.

7.

Change the value by entering cimom.snmpTrapListenerCommunityString=

where is the desired community string value.

8.

Click Save.

This manual is related to the following products: