Faceplate buttons, Reset, Init – Nortel Networks 1000 User Manual
Page 943: Dip switch, Led indicators, Status led, Active cpu led
![background image](/manuals/193391/943/background.png)
LED indicators
943
Faceplate buttons
Reset
Reset (RST) generates a hard reset of the card.
Init
Init (INI) generates a manual initialization of the software.
DIP switch
The DIP switch selects the media drive. CF MASTER/POSITION1 selects
the Compact Flash (CF) FMD and HD MASTER/POSITION2 selects the
Hard Drive FMD.
LED indicators
Status LED
The functionality of the Status LED is summarized in the following table.
Table 399
Status LED functionality
LED
Color
CP PM Status
Status
Green
After sysload
Flashing Green
Not implemented
Yellow
Not implemented
Orange
Selftest error
Red
During sysload phase 2
Flashing Red
During sysload phase 1
Off
No power
Active CPU LED
The CP PM can operate in single CPU mode or dual CPU mode. A
tri-color LED indicates the Call Server redundancy status. This LED is not
used by the Signaling Server and is OFF if it is a Signaling Server. The
functionality of the active CPU LED is summarized in the following table.
Table 400
Call server redundancy status
LED
Color
Status
Call server redundancy
Green
Redundant mode, active
Yellow
Redundant mode, standby
Red
Redundant mode, fault (HSP
down)
Off
Standard mode
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008