Serial data interface ports

The MGC has three serial data interface (SDI) ports. The ports can be
used locally for debugging, or they can be configured in the CS 1000E Call
Sever as system terminals. Only ports SDI 0 and SDI 1 can be used to
access the installation menu during initial configuration of the MGC. SDI
2 is not available during bootup. Due to a limitation of the three port cable
used, SDI 1 and SDI 2 do not use hardware flow control. Only SDI 0 has
full modem support.

TTY default settings

The default tty settings for the SDI ports are:

Baud rate: 9600.

Data bit length: 8.

Stop bit: 1.

Parity: none.

Flow control: none.

MGC serial port configuration change

If the serial ports are configured as SL1 terminals on the Call Server,
the tty default settings can be changed in LD 17. Any values configured
in LD 17 are downloaded to the MGC and override default values. The
downloaded values persist over restarts and power outages. A system
message is output when the serial port baud rate is changed.

Faceplate LED display

The faceplate on the MGC card has a four character LED display.

The diagnostic messages summarized in the following table are displayed
on the faceplate.

Table 398
Faceplate display

Message

Description

BOOT

This is the first message displayed when the system becomes active.

POST

Power on self test. This message is displayed when the MGC is carrying
out system tests during power up.

PASS

Power on self test pass.

EXXX

Error code. XXX is a numeric value. An error code is displayed if a
serious system error is detected.