Software service changes – Nortel Networks 1000 User Manual
Page 443

Configuration
443
The NT8D02GA, NT8D02HA, and NT8D02HAE5 Cards are based on a
different architecture and hence need a jumper (J1) to activate/deactivate
the unterminated line detection feature. When connected to digital sets,
the jumper J1 should be removed. This enables the unterminated line
detection feature. This jumper settings is applicable only to NT8D02GA ,
NT8D02HA, and NT8D02HAE5 packs.
Software service changes
Voice and data ports are configured using LD 11. See Software
Input/Output Reference — Administration (NN43001-611) for LD 11
service change instructions. Voice and data ports are configured using
the Meridian Digital TelephoneAdministration program LD 11. See the
Software Input/Output Reference — Administration (NN43001-611) for LD
11 service change instructions.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008