Power requirements – Nortel Networks 1000 User Manual
Page 693
![background image](/manuals/193391/693/background.png)
Electrical specifications
693
Table 261 "Electrical characteristics" (page 692)
lists the electrical
characteristics of the trunk interface on the E and M Trunk card.
Table 262
Electrical characteristics of the E and M Trunk interface
Characteristic
4-wire trunk
2-wire trunk
Signaling range
Type I
150 ohms
Type II 300 ohms loop
Type I 150 ohms
Signaling type
Type I, Type II
Type I
Far-end battery
–42 to –52.5 V dc
–42 to –52.5 V dc
Near-end battery
–42.75 to –52.5 V dc
–42.75 to –52.5 V dc
Ground potential difference
±10 V dc
±10 V dc
Line leakage between E lead
and ground
ˇ
S20K ohms
³20K ohms
Effective loss
See pad table
(
See pad table
Terminating impedance
600 ohms
600 ohms
Balance impedance
N/A
600 ohms
Power requirements
Table 263 "Power requirements" (page 693)
lists the power requirements
for the E and M Trunk card.
Table 263
Power requirements
Voltage
Tolerance
Max current
+15.0 V dc
±5%
200 mA
–15.0 V dc
±5%
200 mA
+8.5 V dc
±2%
200 mA
–48.0 V dc
±5 %
415 mA
Table 264 "Power requirements" (page 693)
lists the power requirements
for the E and M Trunk card.
Table 264
Power requirements
Voltage
Tolerance
Max current
+15.0 V dc
±5%
200 mA
–15.0 V dc
±5%
200 mA
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.