Man-Machine T1 maintenance interface software
221
For single card installations, log in by entering:
L
For multiple card installations connected in a daisy-chain, log in by
entering:
L
where the four-digit address is the two-digit address of the IPE shelf as
set by dip switch positions (dip switch #1, positions 3-6) on the card (as
opposed to the address set in the CS 1000 software), plus the two-digit
address of the card slot that the motherboard occupies. For example, to
login to a card located in shelf 13, card slot 4, type:
L 13 4
A space is inserted between the login command (L), the shelf address,
and the card slot address.
The MMI then prompts for a password. The password is "LTILINK", and it
must be typed all in capital letters.
After logging in, the prompt looks like the following:
•
LTI:::>
for single-card installations
•
LTI:ss cc>
for multi-card installations, where ss represents the
two-digit address, and cc represents the two-digit card slot address
The MMI can be accessed through a TTY, a PC running a terminal
emulation program, or a modem. After installing the MMI terminal and card
cables, the MMI firmware can be accessed.
For single card installations, it is accessed by entering
L
to login.
For multiple card installations connected in a daisy-chain, it is accessed
by entering
L
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008