beautypg.com

L

Page 221

background image

Man-Machine T1 maintenance interface software

221

For single card installations, log in by entering:

L

For multiple card installations connected in a daisy-chain, log in by
entering:

L

where the four-digit address is the two-digit address of the IPE shelf as
set by dip switch positions (dip switch #1, positions 3-6) on the card (as
opposed to the address set in the CS 1000 software), plus the two-digit
address of the card slot that the motherboard occupies. For example, to
login to a card located in shelf 13, card slot 4, type:

L 13 4

A space is inserted between the login command (L), the shelf address,
and the card slot address.

The MMI then prompts for a password. The password is "LTILINK", and it
must be typed all in capital letters.

After logging in, the prompt looks like the following:

LTI:::>

for single-card installations

LTI:ss cc>

for multi-card installations, where ss represents the

two-digit address, and cc represents the two-digit card slot address

The MMI can be accessed through a TTY, a PC running a terminal
emulation program, or a modem. After installing the MMI terminal and card
cables, the MMI firmware can be accessed.

For single card installations, it is accessed by entering

L

to login.

For multiple card installations connected in a daisy-chain, it is accessed
by entering

L

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.