Power requirements – Nortel Networks 1000 User Manual
Page 125
Electrical specifications
125
Table 50
OPS analog line card - electrical characteristics (cont’d.)
Characteristic
Specification
Line leakage
≥
30k ohms, tip-to-ring, tip-to-ground,
ring-to-ground
AC induction rejection
10 V rms, tip-to-ring, tip-to-ground,
ring-to-ground
Table 50 "OPS analog line card - electrical characteristics" (page 124)
lists
the electrical characteristics of OPS analog line card line interface units.
Power requirements
Table 51 "OPS analog line card - power requirements" (page 125)
shows
the maximum power consumed by the card from each system power
supply.
Table 51
OPS analog line card - power requirements
Voltage
Tolerance
Current (max.)
±15.0 V dc
± 5%
150 mA
+8.5 V dc
± 2%
200 mA
+5.0 V dc
± 5%
100 mA
–48.0 V dc
± 5%
350 mA
The +8.5 V dc input is regulated down to +5 V dc for use by the digital
logic circuits. All other power to the card is used by the line interface
circuits.
The +8.5 V dc input is regulated down to + 5 V dc for use by the digital
logic circuits. All other power to the card is used by the line interface
circuits.
The +8.5 V dc input is regulated down to +5 V dc for use by the digital
logic circuits. All other power to the card is used by the line interface
circuits. The ±15.0 V dc inputs to the card are used to power the analog
circuits. The +5 V dc from the module power supply is used for the analog
hybrid. The
–48.0 V dc input is for the telephone battery. Ringing power for telephones
is 86 Vrms ac at 20 Hz on –48 V dc. The Rsync signal is used to switch
the 20 Hz ringing on and off at the zero cross-over point to lengthen the
life of the switching circuits.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008