Table 225 "jumper strap settings - extended, Table 226 "trunk types - termination, Table 226 "trunk types – Nortel Networks 1000 User Manual
Page 608
608
NT8D14 Universal Trunk card
Table 225
Jumper strap settings - extended range (NT8D14BA, NT8D14BB, NT8D14BB)
Jumper strap settings (Note 1)
Trunk types
Loop length
J1.X
J2.X
J3.X
J4.X
(Note 2)
CO/FX/WATS
2-way TIE (LDR)
2-way TIE (OAID)
> 1524 m (5000 ft.)
Off
Off
1–2
2–3
DID
> 600 ohms
On
On
1–2
2–3
RAN: pulse start or
level start modes
Not applicable: RAN
trunks should not leave
the building.
Off
Off
2–3
1–2
Note 1: Jumper strap settings J1.X, J2.X, J3.X, and J4.X apply to all eight units; "X" indicates the
unit number, 0–7. "Off" indicates that no jumper strap is installed on a jumper block.
Note 2: For the NT8D14BB card, J4.X is not provided on the board. The J4.X jumper setting
specified in
Table 225 "Jumper strap settings - extended range (NT8D14BA, NT8D14BB,
does not apply.
Table 226
Trunk types - termination impedance and balance network (NT8D14BA, NT8D14BB)
Balance network for loop lengths (Note 2)
Trunk types
Terminating
impedance
(Note 1)
0–915 m
(0–3000 ft)
915–1524 m
(3000–5000 ft)
> 1524 m
(> 5000 ft)
CO/FX/WATS
600 or 900
ohms
600 ohms
3COM
3CM2
2-way TIE (LDR)
600 or 900
ohms
600 ohms
3COM
3CM2
2-way TIE (OAID)
600 or 900
ohms
600 ohms
3COM
3CM2
DID (loop length <
600 ohms)
600 or 900
ohms
600 ohms
3COM
3CM2
DID (loop length ˇ
S
600 ohms)
600 or 900
ohms
600 ohms
N/A
3CM2
Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and should
match the nominal impedance of the connecting equipment.
Note 2: The balance network of each trunk unit is software selectable between resistive 600 or
900 ohms or 3COM and jumper selectable between 3COM and 3CM2. Jumper selection for
3COM/3CM2 restriction does not apply to NT8D14BB.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.