beautypg.com

Nortel Networks 1000 User Manual

Page 189

background image

Installation and configuration

189

Table 78
Lineside T1 card - XPEC address dip switch settings (Switch S1, positions 3 - 6) (cont’d.)

XPEC

Address

S1 Switch
Position 3

S1 Switch
Position 4

S1 Switch
Position 5

S1 Switch
Position 6

02

Off

Off

On

Off

03

Off

Off

On

On

04

Off

On

Off

Off

05

Off

On

Off

On

06

Off

On

On

Off

07

Off

On

On

On

08

On

Off

Off

Off

09

On

Off

Off

On

10

On

Off

On

Off

11

On

Off

On

On

12

On

On

Off

Off

13

On

On

Off

On

14

On

On

On

Off

15

On

On

On

On

Table 79
Lineside T1 card - T1 Switch 2 (S2) dip switch settings

Dip Switch

Number

Characteristic

Selection

1

T1 framing

On = D4
Off = ESF

2

T1 Coding

On = AMI
Off = B8ZS

3–5

CPE or CSU distance

See

Table 80 "Lineside T1 card -

CPE or CSU distance dip switch
settings (Switch S2, positions 3
- 5)" (page 190)

6

Line processing on T1 link failure

On = On-hook
Off = Off-hook

7

Daisy-chaining to MMI

On = Yes
Off = No

8

MMI Master or Slave

On = Master
Off = Slave

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.