Qpc841 4-port serial data interface card – Nortel Networks 1000 User Manual
Page 104
![background image](/manuals/193391/104/background.png)
104
Option settings
Table 44
QPC441 3PE card installed in the NT8D35 module (cont’d.)
0
on
on
on
off
1
on
on
off
off
1
2
on
off
on
off
3
on
off
off
off
4
off
on
on
off
5
off
on
off
off
6
off
off
on
off
7
off
off
off
off
QPC841 4-Port Serial Data Interface card
Table 45 "QPC841 port 1 and 2 address selection" (page 104)
through
Table 47 "QPC841 DTE or DCE selection" (page 105)
list option settings
for the QPC841 4-Port SDI card.
Table 45
QPC841 port 1 and 2 address selection
Device number
SW14
Port 1
Port 2
1
2
3
4
5
6
7
8
0
1
off
off
off
off
off
on
on
on
2
3
off
off
off
off
off
on
on
off
4
5
off
off
off
off
off
on
off
on
6
7
off
off
off
off
off
on
off
off
8
9
off
off
off
off
off
off
on
on
10
11
off
off
off
off
off
off
on
off
12
13
off
off
off
off
off
off
off
on
14
15
off
off
off
off
off
off
off
off
Note 1: On SW16, positions 1, 2, 3, and 4 must be OFF.
Note 2: To avoid address conflicts, SW14 and SW15 can never show identical settings.
Note 3: To disable ports 1 and 2, set SW14 position 1 to ON.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.