Carrier grounding – Nortel Networks 1000 User Manual
Page 881
![background image](/manuals/193391/881/background.png)
Architecture
881
Table 374
Impedance matching switch settings
Cable Type
SW 2-1
75
3
/
4
Down (On)
120
3
/
4
Up (Off)
Note:
The ON position for all the switches is towards the bottom of the
card. This is indicated by a white dot printed on the board adjacent to
the bottom left corner of each individual switch.
The line interface provides for the use of either 75 ohms coaxial or 120
ohms twisted pair cable. The impedance is selected by SW2, as shown in
Table 375 "Impedance matching switch settings" (page 881)
.
Table 375
Impedance matching switch settings
Cable Type
SW 2-1
75 ohms
Down (On)
120 ohms
Up (Off)
Note:
The ON position for all the switches is toward the bottom of the
card. This is indicated by a white dot printed on the board next to the
bottom left corner of each individual switch.
Carrier grounding
NTBK50 enables the shield of the Tx and/or Rx pairs of the carrier to be
selectively grounded. Closing (down position) the on-board switch applies
FGND to the appropriate carrier cable shield. The switch settings are
shown in
Table 376 "Carrier Shield grounding switch settings" (page 881)
.
Table 376
Carrier Shield grounding switch settings
Switch
Down (On)
Up (Off)
SW 4 – 1
Rx – FGND
Rx – OPEN
SW 4 – 2
Tx – FGND
Tx – OPEN
NTBK50 provides for the capability of selectively grounding the shield of
the Tx and/or Rx pairs of the carrier. Closing (down) the on-board switch
applies FGND to the appropriate carrier cable shield. The switch settings
are shown below.