beautypg.com

General purpose switches, Trunk interface switches – Nortel Networks 1000 User Manual

Page 83

background image

NT5D12 Dual DTI/PRI (DDP) card

83

General purpose switches

Use switch set SW9 for Trunk 0; use switch set SW15 for Trunk 1 (see

Table 14 "General purpose switch settings" (page 83)

).

Table 14
General purpose switch settings

Switch

Description

SW9/SW15
switch setting

1

Framing Mode

off - ESF

on - SF

2

Yellow Alarm Method

off - FDL

on - Digit2

3

Zero Code Suppression Mode

off - B8ZS

on - AMI

4

Unused

off

Trunk interface switches

A switch provides selection of T1 transmission. Use switch SW4 for
Trunk 0; use switch SW10 for Trunk 1 (see

Table 15 "Trunk interface

transmission mode switch settings" (page 83)

).

Table 15
Trunk interface transmission mode switch settings

Description

SW4/SW10 switch setting

For future use

off

T1

on

A set of three switches provides selection of dB values. Use SW5, SW6,
and SW7 for Trunk 0; use SW11, SW12, and SW13 for Trunk 1 (see

Table

16 "Trunk interface line build out switch settings" (page 83)

).

Table 16
Trunk interface line build out switch settings

Switch Setting

Description

SW5/SW11

SW6/SW12

SW7/SW13

0 dB

off

off

off

7.5 dB

on

on

off

15 dB

on

off

on

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.