Installation and configuration – Nortel Networks 1000 User Manual
Page 266
![background image](/manuals/193391/266/background.png)
266
NT5D33 and NT5D34 Lineside E1 Interface cards
Table 100
LEI card - environmental specifications
Parameter
Specifications
Operating temperature – normal
15
to +30
C (+59
to 86
F), ambient
Operating temperature – short term
10
to +45
C (+50 to 113
F), ambient
Operating humidity – normal
20% to 55% RH (non-condensing)
Operating humidity – short term
20% to 80% RH (non condensing)
Storage temperature
–50
to + 70
C (–58
to 158
F), ambient
Storage humidity
5% to 95% RH (non-condensing)
Installation and Configuration
Installation and configuration of the LEI consists of six basic steps:
Step
Action
1
Configure the dip switches on the LEI for the call environment.
2
Install the LEI into the selected card slots.
3
Cable from the I/O panel to the LTU, MMI terminal or modem
(optional), external alarm (optional), and other LEIs for daisy
chaining use of MMI terminal (optional).
4
Configure the MMI terminal.
5
Configure the LEI through the CS 1000 software and verify
self-test results.
6
Verify initial E1 operation and configure MMI (optional).
Steps 1-5 are explained in this section. Step 6 is covered in
“Man-Machine E1 maintenance interface software” (page 284)
.
Installation and configuration of the ELEI follows the same steps.
If enhanced functionality is required, then one additional step is
required:
7
The Meridian 1 line unit(s) associated with the lineside E1 must
be programmed for wireless operation (set WTYP=DECT,
and WRLS=Yes in LD 10) in non–concentrated mode.
Refer to Software Input/Output Reference — Administration
(NN43001-611) details on LD 10.
--End--
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008