NT5D33 and NT5D34 Lineside E1 Interface cards

Table 100
LEI card - environmental specifications

Parameter

Specifications

Operating temperature – normal

15

to +30

C (+59

to 86

F), ambient

Operating temperature – short term

10

to +45

C (+50 to 113

F), ambient

Operating humidity – normal

20% to 55% RH (non-condensing)

Operating humidity – short term

20% to 80% RH (non condensing)

Storage temperature

–50

to + 70

C (–58

to 158

F), ambient

Storage humidity

5% to 95% RH (non-condensing)

Installation and Configuration

Installation and configuration of the LEI consists of six basic steps:

Step

Action

1

Configure the dip switches on the LEI for the call environment.

2

Install the LEI into the selected card slots.

3

Cable from the I/O panel to the LTU, MMI terminal or modem
(optional), external alarm (optional), and other LEIs for daisy
chaining use of MMI terminal (optional).

4

Configure the MMI terminal.

5

Configure the LEI through the CS 1000 software and verify
self-test results.

6

Verify initial E1 operation and configure MMI (optional).

Steps 1-5 are explained in this section. Step 6 is covered in

“Man-Machine E1 maintenance interface software” (page 284)

.

Installation and configuration of the ELEI follows the same steps.
If enhanced functionality is required, then one additional step is
required:

7

The Meridian 1 line unit(s) associated with the lineside E1 must
be programmed for wireless operation (set WTYP=DECT,
and WRLS=Yes in LD 10) in non–concentrated mode.
Refer to Software Input/Output Reference — Administration
(NN43001-611) details on LD 10.

--End--