Overview
Instructions for cabling the serial data interface cards to the various system
consoles and peripherals are found in Communication Server 1000M and
Meridian 1 Large System Installation and Configuration (NN43021-310).
Configuring the system software
Once an SDI card has been installed in the system, the system
software needs to be configured to recognize it. This is done using the
Configuration Record program LD 17. Instructions for the Configuration
Record program are found in Software Input/Output Reference —
Administration (NN43001-611).
Maintenance
The following maintenance programs are used to maintain individual SDI
asynchronous ports. The program used depends on the application of the
port.
•
LD 37 Input/Output Diagnostics – Used for system terminal, printer,
background terminal ports, and system monitor status.
•
LD 42 Call Detail Recording (CDR) Diagnostic – For checking CDR
links and CDR system terminals.
The following maintenance program is used to maintain individual SDI
synchronous ports.
•
LD 48 Link Diagnostic – For checking Automatic Call Distribution
(ACD) and Meridian Link ports.
Instructions for running the various maintenance programs are found
in Software Input/Output Reference — Administration (NN43001-611).
System messages are interpreted in Software Input/Output Reference —
System Messages (NN43001-712).