Nortel Networks 1000 User Manual
Page 184
![background image](/manuals/193391/184/background.png)
184
NT5D11 and NT5D14 Lineside T1 Interface cards
Table 73
Lineside T1 card-T1 Switch 1 (S1) dip switch settings (cont’d.)
Dip Switch
Number
Characteristic
Selection
3–6
XPEC Address for the Lineside T1 card
See
card - XPEC address dip
switch settings (Switch S1,
positions 3 - 6)" (page 184)
7
Not Used
Leave Off
8
Reserved for SL-100 use
Leave Off
Table 74
Lineside T1 card - XPEC address dip switch settings (Switch S1, positions 3 - 6)
XPEC
Address
S1 Switch
Position 3
S1 Switch
Position 4
S1 Switch
Position 5
S1 Switch
Position 6
00
Off
Off
Off
Off
01
Off
Off
Off
On
02
Off
Off
On
Off
03
Off
Off
On
On
04
Off
On
Off
Off
05
Off
On
Off
On
06
Off
On
On
Off
07
Off
On
On
On
08
On
Off
Off
Off
09
On
Off
Off
On
10
On
Off
On
Off
11
On
Off
On
On
12
On
On
Off
Off
13
On
On
Off
On
14
On
On
On
Off
15
On
On
On
On
Table 75
Lineside T1 card - T1 Switch 2 (S2) dip switch settings
Dip Switch
Number
Characteristic
Selection
1
T1 framing
On = D4
Off = ESF
2
T1 Coding
On = AMI
Off = B8ZS
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.