Display history – Nortel Networks 1000 User Manual
Page 303
![background image](/manuals/193391/303/background.png)
Man-Machine E1 maintenance interface software
303
Figure 73
Display Performance (D P) screen
Each column, except the error counter, indicates the number of errors in
the current hour and is reset to zero every hour on the hour. Just before
the performance counters are reset to zero, the values are put into the
history log.
The error counter indicates the number of errors since the error counter
was cleared.
The Pause command can be used to display a full screen at a time, by
entering
D P P
. If more than one screen is to be displayed, the MMI scrolls
until the screen is full, then stops. When ready to see the next screen,
press any key. The display shows one more screen, and stops again. This
continues until the entire display has been shown.
Display History
Entering the
Display History (D H)
command displays performance
counters for each hour of the past 24 in reverse chronological order,
beginning with the last full hour. A screen similar to
History (D H) screen" (page 304)
appears.
The Pause command works the same for Display History as it does for
the other display commands. Simply enter
D H P
to see a report on the
performance counters, one screen at a time.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.