Table 294
NT8D41BA DTE/DCE/Fiber switch settings (cont’d.)
Port 1 — SW 3
Port 1 —SW 2
Mode
1
2
3
4
5
6
1
2
3
4
5
6
NT1P61 (Fiber)
on on on on on of
f
on on on of
f
on of
f
Port 3 — SW 7
Port 3— SW 6
DTE (terminal)
on on on of
f
on of
f
of
f
on of
f
on of
f
on
DCE (modem)
of
f
of
f
of
f
on of
f
on on of
f
on of
f
on of
f
NT1P61 (Fiber)
on on on on on of
f
on on on of
f
on of
f
Port 4 — SW 9
Port 4 — SW 8
DTE (terminal)
on on on of
f
on of
f
of
f
on of
f
on of
f
on
DCE (modem)
of
f
of
f
of
f
on of
f
on on of
f
on of
f
on of
f
NT1P61 (Fiber)
on on on on on of
f
on on on of
f
on of
f
Software service changes
Once the NT8D841BA QSDI paddle board has been installed in the
system, the system software needs to be configured to recognize it, using
the Configuration Record program LD 17. Instructions for running this
program are found in Software Input/Output Reference — Administration
(NN43001-611).
Some of the prompts that are commonly used when running the
Configuration Record program LD 17 are shown in
. These parameters must be set for each port if both ports
are being used.
Applications
The NT8D41BA Quad Serial Data Interface paddle board is used to
connect the Meridian 1 switch to a variety of communications devices,
printers, and peripherals. Any RS-232-C compatible device can be
connected to either of the card’s two serial ports.
The standard application for the paddle board is to connect the Meridian
1 switch to the system console. This can be either a direct connection
if the console is located near the switch, or through a modem for remote
maintenance.