Nortel Networks 1000 User Manual
Page 741
![background image](/manuals/193391/741/background.png)
Introduction
741
Table 296
XMFR receiver specifications (cont’d.)
Noise Rejection:
Error Rate in White Noise
Better than: < 1/2500 calls
Test:
10 digit calls
nominal frequency @ -23 dBmO
ON/OFF = 50 ms/50ms
KP duration 100 ms
SNR = -20 dB
all digits
Immunity to Impulse Noise
Better than: < 1/2500 calls
Test:
10 digit calls
nominal frequency @ -23 dBmO
ON/OFF = 50ms/50ms
KP duration 100 ms
SNR = -12 dBs
all digits
ATT Digit Simulation Test, Tape #201 from PUB
56201
Error Rate from Power Lines
Better than: < 1/2500 calls
Test:
10 digit calls
nominal frequency @ -23 dBmO
ON/OFF = 50 ms/50ms
KP duration 100 ms
60 Hz signal @ 81 dBrnc0 (-9dBm)
or
180 Hz signal @ 68 dBrnco (-22dBm)
all digits
Tolerate Intermodulation:
Must tolerate @A-B and @B-A modulation products with a
power sum
28 dB below each frequency component level of the
signals.
KP:
KP activation
The receiver must not respond to signals prior to KP.
Remain unlocked until ST, STP, ST2P or ST3P is
received.
Multiple KP’s
After the initial KP, subsequent KP’s are ignored while in
unlocked mode.
Excessive Components:
If more than two valid frequencies are detected, no digit is
reported to the CPU.
The XMFR receiver specifications conform to the following:
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.