Digitone receiver cards, Procedure 4, Line cards – Nortel Networks 1000 User Manual

Page 72: Procedure 5

background image

72

Acceptance tests

Digitone receiver cards

Note:

The DTR daughterboard connected to a QPC659 Dual Loop

Peripheral Buffer card cannot be assigned when the IPE shelf is used
in single loop mode.

Procedure 4
Testing digitone receiver cards

Step

Action

Use this procedure to test a Digitone receiver (DTR) card, a DTR daughterboard,
or the DTR function on the NT8D18 Network/DTR card.

1

Log into the system:

LOGI

(password)

2

See if the Digitone receiver to be tested is disabled:

LD 34

STAT

The system responds with the terminal number (TN), or
numbers, of any disabled Digitone receivers.

3

If the Digitone receiver is disabled, enable it:

ENLR l s c u

loop, shelf, card, and unit numbers

4

Test the Digitone receiver:

DTR l s c u

loop, shelf, card, and unit numbers

If the system response is other than OK, seeSoftware
Input/Output Reference — Administration
(NN43001-611) to
analyze the messages.

5

End the session in LD 34:

****

--End--

Line cards

Procedure 5
Testing line cards

Step

Action

Use this procedure to test a line card.

1

Log into the system:

LOGI

(password)

2

Perform a network memory test, continuity test, and signaling
test on a specific loop and shelf:

LD 30
SHLF l s

loop and shelf numbers

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.