Man-Machine E1 maintenance interface software
297
Figure 69
Set Mode (S M): Table screen
Incoming call Ringer ON SEND – This is the value that the LEI sends to
indicate that a call is incoming to the CPE and that ringing voltage should
be applied at the CPE. This value is required.
Incoming call Ringer OFF SEND – This is the value that the LEI sends to
indicate that a call is incoming to the CPE and that the ring cycle is in the
off portion of the cadence. This value is required.
Incoming call Offhook RECEIVE – This is the value that the LEI expects
to see from the CPE when the customer equipment has gone to an off
hook state which indicates that the incoming call has been answered. This
value is required.