Tone and digit switch cards, Procedure 11 – Nortel Networks 1000 User Manual
Page 76
76
Acceptance tests
3
To test a trunk from a remote test center, seize a central office
(CO) monitor trunk:
CALL
or
CALL l s c u
Seize the automatic number identification (ANI) trunk:
TRK l s c
u
loop, shelf, card, and unit numbers
When you see the
DN?
prompt, enter the directory number (DN)
you want the system to dial.
If the system response is other than OK, see the Software
Input/Output Reference — Administration (NN43001-611) to
analyze the messages.
4
End the session in LD 36:
****
5
Test an automatically identified outward dialing (AIOD) trunk
card:
LD 41
AIOD l s c
loop, shelf, and card numbers
If the system response is other than OK, see Software
Input/Output Reference — Administration (NN43001-611) to
analyze the messages.
6
End the session in LD 41:
****
--End--
Tone and digit switch cards
Procedure 11
Testing tone and digit switch cards
Step
Action
Use this procedure to test a tone and digit switch (TDS) card or to test the TDS
function of an NT8D17 Conference/TDS card.
1
Log into the system:
LOGI
(password)
2
Obtain a list of terminal numbers (TNs) for disabled TDS cards:
LD 34
STAD
3
If the TDS loop to be tested is disabled, enable it.
For an NT8D17 Conference/TDS card, enter:
ENLX loop
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.