Each of the four trunk circuits on the E and M trunk card can be
individually configured for trunk type, companding mode, and port-to-port
loss compensation. Configuring the card requires both jumper changes
and configuration software service entries.

The locations of the jumpers are shown in

Figure 239 "E and M Trunk card

- jumper locations" (page 704)

.

Each of the four trunk circuits on the E and M trunk card can be
individually configured for trunk type, companding mode, and port-to-port
loss compensation. Configuring the card requires both jumper changes
and configuration software service entries.

Jumper settings

The NT8D15 E and M Trunk card serves various transmission
requirements. The four units on the card can operate in A-Law or µ-Law
companding modes, which are selected by service change entries. Each
unit can be independently configured for 2-wire E and M, 4-wire E and
M, and paging trunk types. The trunk type is selected by service change
entries and jumper strap settings.

See

Table 277 "E and M Trunk card - jumper strap settings" (page 705)

.