Trunk unit functions – Nortel Networks 1000 User Manual
Page 649
![background image](/manuals/193391/649/background.png)
Functional description
649
—
Near-end seizure and outpulsing with M lead
—
Ground detection with E lead
—
Voice transmission through Tip and Ring for transmit and receive
•
Four-wire E and M signaling type I and II, two-way dial repeating (ESN
and Non-ESN)
—
echo suppression for type I
—
Switchable seven dB and 16 dB for carrier interface for ESN
applications
—
Transmit and receive of voice through two separate paths
•
Type I signaling through E and M leads
—
Type II signaling
–
Near-end seizure with MA/MB leads
–
Far-end detection with EA/EB leads
•
Paging trunk loop OAID operation
—
Support access by low resistance path at the PA/PB lead.
—
All call zone paging is not supported.
•
Two to four-wire conversion of the transmission path
Trunk unit functions
The functions provided by each unit on the E and M Trunk card include
2-wire signaling, 4-wire signaling, and paging operation as follows:
•
2-wire, E and M Type I signaling (see
) with:
—
near-end seizure and outpulsing with M lead
—
ground detection with E lead
—
voice transmission through tip and ring for transmit and receive
•
4-wire, E and M Type I and II signaling (see
), 2-way dial repeating with:
—
echo suppression for Type I signaling
—
switchable 7 dB and 16 dB pads for carrier interface
—
voice transmission and reception through two separate paths
—
Type I signaling through E and M leads
—
Type II signaling with near-end seizure by SB/M leads and far-end
detection by E/SG lead
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.