Table 104 "lei card - e1 switch 2 (s2) dip switch, Table – Nortel Networks 1000 User Manual
Page 271
Installation and Configuration
271
Table 103
LEI card - XPEC address dip switch settings (Switch S1, positions 3-6) (cont’d.)
XPEC
Address
S1 Switch
Position 3
S1 Switch
Position 4
S1 Switch
Position 5
S1 Switch
Position 6
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
When setting E1 Switch 2 dip switch settings, there are differences
between vintages. For NT5D33AB or NT5D34AB cards, use
104 "LEI card - E1 Switch 2 (S2) dip switch settings" (page 271)
. For
NT5D33AC or NT5D34AC cards, use
Table 104 "LEI card - E1 Switch 2
(S2) dip switch settings" (page 271)
.
Table 104
LEI card - E1 Switch 2 (S2) dip switch settings
Characteristic
Selection
Switch
Position
Switch
Setting
Factory
Default
E1 framing
CRC-4 Disabled
CRC-4 Enabled
1
ON
OFF
OFF
E1 coding
AMI
HDB3
2
ON
OFF
OFF
NOT USED
leave ON
3
ON
ON
NOT USED
leave ON
4
OFF
OFF
NOT USED
leave ON
5
OFF
OFF
Line processing on E1 link
failure
On-hook
Off-hook
6
ON
OFF
ON
Daisy-chaining to MMI
YES
NO
7
ON
OFF
OFF
MMI master or slave
Master
Slave
8
ON
OFF
ON
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.