Trunk data block – Nortel Networks 1000 User Manual
Page 912
912
NTCK16 Generic Central Office Trunk cards
Table 391
LD 16 - Route Data Block for NTCK16BX.
Prompt
Response
Description
REQ:
NEW
Define a new unit
TYPE:
COT
Define a new Route Data Block
CUST
xx
Customer number as defined in LD 15.
ROUT
Route number
0-511
Range for Large System, Call Server 1000E,
and Media Gateway 1000E
0-127
Range for Small System, CS 1000E system,
Media Gateway 1000B, and
Media Gateway 1000T
TKTP
COT
Define trunk type as Central Office
ICOG
IAO
Incoming and Outgoing trunk
CNTL
YES
Change a trunk timer
TIMER
RGV 256
Set Ring Validation Timer to 128 ms.
MR
(NO)
PPM is off on this route.
Trunk Data Block
Respond to the prompts in LD 14.
Table 392
LD 14 - Trunk Data Block for NTCK16BX
Prompt
Response
Description
REQ:
NEW
Define a new trunk unit.
TYPE:
COT
Central Office Trunk
TN
Terminal Number
l s c u
Format for Large System, Call Server 1000E,
and Media Gateway 1000E, where l = loop, s =
shelf, c = card, u = unit
XTRK
(See note
XCOT
Type is IPE COT
CDEN
(8D)
Card density is 8D (default).
SIGL
LOP
Loop start signaling
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.