Applications, Periodic pulse metering, Detection limits – Nortel Networks 1000 User Manual
Page 914: Busy tone detect, Loss switching
![background image](/manuals/193391/914/background.png)
914
NTCK16 Generic Central Office Trunk cards
Applications
Periodic Pulse Metering
All trunk units on the NTCK16AX trunk card can be individually configured
to support the Periodic Pulse Metering (PPM) feature.
Note:
PPM is available on the NTCK16AX trunk card. It is not
supported on the NTCK16BX trunk card.
PPM allows the user of a telephone to keep an accurate record of Central
Office calls for billing or administration purposes.
Detection limits
Pulses detected by the NTCK16AX circuit card must be within the following
limits:
Frequency
11 880 to 12 120 Hz
Level
105 to 1100 mVrms
Note: The pack should not be used to
detect levels of 1100 mVrms or greater
a Tip and Ring, as this may result in
noise.
Pulse length
Dependent on PPID – see LD 14
Busy tone detect
Busy tone is sent by the Central Office to indicate the release of an
established call.
Detection limits
The NTCK16AX and NTCK16BX generic Central Office trunk cards can
detect busy tone within the following limits:
Frequency
400 to 620 Hz
Level
–30 to 0 dBm
Cadence
See on
Loss switching
The Generic XFCOT is based on the XFCOT design, which is using a
static pad download algorithm by default for its loss plan.
The generic XFCOT has to be set explicitly to a Dynamic Pad Switching
mode to make it compliant with the standard North American Dynamic Pad
Switching mode.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.