Nortel Networks 1000 User Manual
Page 690
![background image](/manuals/193391/690/background.png)
690
NT8D15 E and M Trunk card
Table 257
DX signaling - outgoing calls with originating party release on tandem connections (cont’d.)
Condition
Current in
signaling lead
State of trunk
detector
Dial CO/FX/WATS
Current flow
interrupted for each
pulse
High
Stop sender
No current flow
Low
Go sender (universal service provided by
far-end PBX if originating end is senderized)
Current flow
High
CO/FX/WATS offices ready for digits
Stored Office DN digits
Current flow
interrupted for each
pulse
High
Outpulsed
No current flow
Low
Far-end answers
No current flow
Low
Far-end on hook first
Current flow
High
Near-end on hook, network taken down, trunk
idled
No current flow
High
Near-end on hook first, network taken down
Current flow
Low
Far-end on hook, trunk idled
No current flow
High
Table 258
DX signaling - incoming calls with originating party release on tandem connections
Condition
Current in
signaling lead
State of trunk
detector
Idle
No current flow
High
Seizure
(CS 1000 can be arranged for IS, DD, or WS)
Current flow
Low
Near-end ready for digits
Dial CO/FX/WATS and office DN
Current flow
interrupted for each
pulse
Low-high-low for each
pulse
If a ground start*, the stored digits are sent out
on CO/FX/WATS trunk after ground detection. If
a loop start, the stored digits are outpulsed on
CO/FX/WATS trunk after 3 seconds.
If answer supervision is enabled, pseudo-answe
r supervision is sent approximately 13 seconds
after last dial pulse is received
No current flow
Low
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.