Pad switching, Connector pin assignments, Cross connections – Nortel Networks 1000 User Manual
Page 906: Configuration
![background image](/manuals/193391/906/background.png)
906
NTCK16 Generic Central Office Trunk cards
Pad switching
The NTCK16AX and NTCK16BX generic Central Office trunk cards
support the North American loss plan. Software configuration allows the
selection of 4 dB loss pads on a per unit basis.
Table 388
NTCK16 pad switching
Loss
Analog-to-Digital
Digital-to-Analog
PAD out
0 dB
–3 dB
PAD in
+4 dB
+1 dB
Note:
The tolerance for the above nominal values is +0.3 dB, -0.7 dB.
Connector pin assignments
Cross connections
,
Office trunk connections for NT8D37 I/O panel connectors B, F, L, S"
(page 908)
, and
Figure 260 "NTCK16 Central Office trunk connections
for NT8D37 I/O panel connectors C, G, M, T" (page 909)
provide cross
connect information for the NTCK16AX and NTCK16BX generic Central
Office trunk cards.
Configuration
The trunk type for each unit on the card is selected by software service
change entries at the system terminal.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.