Cable installation, Pri trunk connections, Procedure 18 – Nortel Networks 1000 User Manual
Page 400: I/o panel connections, Procedure 19

400
NT6D80 MSDL card
Cable installation
When the MSDL card is installed, connect the cables to the equipment
required for the selected operation.
PRI trunk connections
D-channel operations require connections between the MSDL and
a PRI trunk card. Refer to ISDN Primary Rate Interface: Features
(NN43001-569) for a complete discussion of PRI and D-channels.
Procedure 18
Cabling the MSDL card to the PRI card
Step
Action
The following steps explain the procedure for cable connection:
1
Identify the MSDL and the PRI cards to be linked.
2
Select the appropriate length cable for the distance between the
MSDL and the PRI card.
3
Plug the 26-pin SCSI II male connector end of a cable into the
appropriate MSDL port.
4
Route the cable through cable troughs, if necessary, to the
appropriate PRI card.
5
Plug the DB15 male connector end of the cable into the J5 DB15
female connector on the PRI card.
6
Secure the connections in place with their fasteners.
7
Repeat steps 1 through 6 for each connection.
--End--
I/O panel connections
Operations aside from PRI require cable connections to the I/O panel.
Procedure 19
Cabling the MSDL card to the I/O panel
Step
Action
The following steps explain the procedure for cable connection:
1
Identify the MSDL card and the I/O panel connector to be linked.
2
Using the NTND27AB cable, plug the 26-pin SCSI II male
connector end of a cable into the appropriate MSDL port.
3
Route the cable to the rear of the module next to the I/O panel.
4
Plug the DB25 male connector end of a cable into a DB25
female connector at the back of the I/O panel.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.