beautypg.com

Nortel Networks 1000 User Manual

Page 208

background image

208

NT5D11 and NT5D14 Lineside T1 Interface cards

alarm connections, MMI connections are optional. Up to 128 Lineside T1
cards, located in up to 16 separate IPE shelves, can be linked to one MMI
terminal using the daisy chaining approach.

If only one Lineside T1 card is being installed, cable from the DB9 female
connector labeled "P5" (towards MMI terminal) to one of the COM ports
on the back of any TTY, a PC running a terminal emulation program, or a
modem. For installations of only one card, no connection is made to the
DB9 male connector labeled "P4" (away from MMI terminal).

If two or more Lineside T1 cards are being installed into the Meridian 1
system, the MMI port connections can be daisy-chained together so that
only one MMI terminal is required for up to 128 Lineside T1 cards. See

Figure 37 "Lineside T1 card - connecting two or more cards to the MMI"
(page 209)

. Cards can be located in up to 16 separate IPE shelves. Any

card slot in the IPE shelf can be connected to any other card slot; the card
slots connected together do not need to be consecutive.

Follow this procedure for connecting two or more Lineside T1 cards to the
MMI terminal:

Step

Action

1

Cable the DB9 male connector labeled "P5" (towards MMI
terminal) to one of the COM ports on the back of any TTY, a PC
running a terminal emulation program, or a modem.

2

Make the connection from the first card to the second card by
plugging the DB9 female connector labeled "P4" (away from MMI
terminal) from the first card into the DB9 male connector of the
second card labeled "P5" (towards MMI terminal).

3

Repeat Step 2 for the remaining cards.

4

When the last card in the daisy chain is reached, make no
connection to the DB9 male connector labeled "P4" (away from
MMI terminal).

5

If two Lineside T1 cards are located too far apart to connect
the "P4" and "P5" connectors together, connect them together
with an off-the-shelf DB-9 female to DB-9 male straight-through
extension cable, available at any PC supply store.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.