beautypg.com

Receiver, Connector pinout – Nortel Networks 1000 User Manual

Page 774

background image

774

NTAK09 1.5 Mb DTI/PRI card

The transmitter takes the binary data (dual unipolar) from the PCM
transceiver and produces bipolar pulses for transmission to the external
digital facility. The DS1 transmit equalizer enables the cabling distance
to extend from the card to the DSX-1 or LD-1. Equalizers are switch
selectable through dip-switches. The settings are shown in

Table 325

"NTAK09 switch settings" (page 774)

.

Table 325
NTAK09 switch settings

Switch Setting

Distance to Digital Cross-Connect

1

DCH F/W

2

(LEN 0)

3

(LEN 1)

4

(LEN 2)

0 - 133 feet

Off

Off

Off

On

133 - 266 feet

Off

On

On

Off

266 - 399 feet

Off

Off

On

Off

399 - 533 feet

Off

On

Off

Off

533 - 655 feet

Off

Off

Off

Off

Receiver

The receiver extracts data and clock from an incoming data stream and
outputs clock and synchronized data. At worst case DSX-1 signal levels,
the line receiver operates correctly with up to 655 feet of ABAM cable
between the card and the external DS1 signal source.

The receiver extracts data and clock from an incoming data stream and
outputs clock and synchronized data. At worst case DSX-1 signal levels,
the line receiver operates correctly with up to 655 feet of ABAM cable
between the card and the external DS1 signal source.

The receiver extracts data and clock from an incoming data stream and
outputs clock and synchronized data. At worst case DSX-1 signal levels,
the line receiver operates correctly with up to 655 feet of ABAM cable
between the card and the external DS1 signal source.

Connector pinout

The connection to the external digital carrier is through a 15-position male
D-type connector. See

Table 326 "DS-1 line interface pinout for NTBK04

cable" (page 774)

.

Table 326
DS-1 line interface pinout for NTBK04 cable

From 50-pin MDF

connector

To DB-15

Signal name

Description

pin 48

pin 1

T

transmit tip to network

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.