Physical description
827
associated with the on-board Clock Controller and the on-board D-channel
interface (DCHI). The LEDs are described in
.
Table 343
NTAK79 LEDs
LED
State
Definition
OOS
On (Red)
The NTAK79 2MB PRI circuit card is disabled or
out-of-service.
Off
The NTAK79 2MB PRI is not in a disabled state.
ACT
On (Green)
The NTAK79 2MB PRI circuit card is in an active state.
Off
The NTAK79 2MB PRI is in a disabled state. The OOS
LED turns red.
RED
On (Red)
A red alarm state has been detected. This represents a
local alarm state of:
Loss of Carrier (LOS)
Loss of Frame (LFAS), or
Loss of CRC Multiframe (LMAS).
Off
No red (local) alarm.
YEL
On (Yellow)
A yellow alarm state has been detected. This represents
a remote alarm indication from the far end. The alarm can
be either Alarm Indication (AIS) or Remote Alarm (RAI).
Off
No yellow (remote) alarm.
LBK
On (Green)
2 MB PRI is in loop-back mode.
Off
2 MB PRI is not in loop-back mode.
On (Red)
The clock controller is switched on and has been disabled
by the software.
On (Green)
The clock controller is switched on and is either locked to
a reference or in free run mode.
CC
Flashing (Green)
The clock controller is switched on and attempting to lock
on to a reference (tracking mode). If the LED flashes
continuously over an extended period of time, check
the CC STAT in LD 60. If the CC is tracking this can be
an acceptable state. Check for slips and related clock
controller error conditions. If none exist, then this state
is acceptable, and the flashing is identifying jitter on the
reference.
DCH
On (Red)
DCH is switched on and disabled.
On (Green)
DCH is switched on and enabled, but not necessarily
established.
Off
DCH is switched off.