beautypg.com

Table 281, Pad switching algorithm, Table 281 "pad switching – Nortel Networks 1000 User Manual

Page 711

background image

Configuration

711

TRC for a 2-wire non-VNL trunk facility with a loss of greater than 2
dB, or for which impedance compensation is provided, or for a 4-wire
non-VNL facility

NTC for a 2-wire, non-VNL trunk facility with a loss of less than 2 dB,
or when impedance compensation is not provided

See

Table 281 "Pad switching algorithm" (page 711)

for the pad switching

control for the various through connections and the actual port-to-port loss
introduced for connections between the E and M Trunk card and any other
IPE or PE port designated as Port B.

Figure 241 "Pad orientation" (page 711)

shows the pad switching

orientation.

Table 281
Pad switching algorithm

Port B pads

E and M Trunk Pads

Port-to-port loss (dB)

Port B

Transmit

D to A

Receive

A to D

Transmit

D to A

Receive

A to D

Port B to

E and M

E and M to

Port B

IPE line

N/A

N/A

Out

In

2.5

3.5

Universal
trunk (TRC)

Out

Out

In

In

0

0

IPE TIE
(VNL)

In

Out

In

Out

0

0

PE line

N/A

N/A

Out

In

3.0

4.0

PE CO/FX/W
ATS (TRC)

Out

Out

In

In

0

0

PE TIE

Out

Out

In

In

0

0

Note: Transmit and receive designations are from and to the Meridian 1. Transmit is from the
Meridian 1 to the external facility (digital-to-analog direction in the E and M Trunk card). Receive is
to the Meridian 1 from the external facility (analog-to-digital direction in the E and M Trunk card).

Figure 241
Pad orientation

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.