Connecting to the ports – Nortel Networks 1000 User Manual
Page 753
![background image](/manuals/193391/753/background.png)
NTAK02 SDI/DCH card
753
Two ports offer the option for DTE/DCE configuration. This option is
selected from a jumper on the card.
Table 310 "Jumper settings" (page
shows the jumper settings.
Table 310
Jumper settings
Port
Jumper location
Strap for
DTE
Strap for
DCE
Jumper
location
RS422
RS232
0
J10
C - B
B - A
1
J7 J6
C - B C
- B
B - A B
- A
J9 J8
C - B C
- B
B - A B
- A
2
J5
C - B
B - A
3
J4 J3
C - B C
- B
B - A B
- A
J2 J1
C - B C
- B
B - A B
- A
Connecting to the ports
External devices are connected to the SDI/DCH card by the following:
•
the NTAK19FB four-port SDI cable. This cable does not have to be
terminated at the cross connect terminal since it is equipped with
connectors.
•
the NE-A25-B cable. Terminate the NE-A25-B cable at the cross
connect terminal. Tables
Table 311 "NTAK02 pinouts - Port 0 at the
cross-connect terminal" (page 753)
through
connections at the cross-connect terminal - Port 3" (page 755)
give
the pinouts for the SDI/DCH card.
Table 311
NTAK02 pinouts - Port 0 at the cross-connect terminal
RS232
Cable
Signal
Designations
I=Input O=Output
Pair
Color
DTE
DCE
DTE
DCE
1T
1R
W-BL
BL-W
0
DTR
0
DCD
—
O
—
I
2T
2R
W-O
O-W
DSR
DCD
CH/CI
DTR
I
I
O
O
3T
3R
W-G
G-W
RTS
CTS
CTS
RTS
O
I
I
O
4T
4R
W-BR
BR-W
RX
TX
TX
RX
I
O
O
I
5T
5R
W-S
S-W
—
SG
—
SG
—
—
—
—
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.