beautypg.com

Clock controller functions and features – Nortel Networks 1000 User Manual

Page 848

background image

848

NTAK79 2.0 Mb PRI card

If the incoming reference is unstable, the internal clock controller remains
continuously in the tracking stage with the LED flashing green all the
time. This condition does not present a problem, rather, it shows that the
clock controller is continually attempting to lock onto the signal. If slips
are occurring, however, it means that there is a problem with the clock
controller or the incoming line.

Free-run (non-tracking)

In free-run mode, the clock controller does not

synchronize on any source, it provides its own internal clock to the system.
This mode can be used when the Option 11C is used as a master clock
source for other systems in the network. Free-run mode is undesirable if
the Option 11C is intended to be a slave. It can occur, however, when both
the primary and secondary clock sources are lost due to hardware faults
or when invoked by using software commands.

Clock controller functions and features

The NTAK79 clock controller functions and features include:

phase lock to a reference, generate the 10.24 MHz system clock, and
distribute it to the CPU through the backplane. Up to two references at
a time are accepted

primary to secondary switchover (auto-recovery is provided)

prevent chatter

error burst detection and correction, holdover, and free running
capabilities

compliance with 2.0Mb CCITT specifications

software communication

jitter filtering

use of an algorithm to detect crystal aging and to qualify clocking
information

The NTAK79 clock controller functions and features include:

phase lock to a reference, generate the 10.24 Mhz system clock, and
distribute it to the CPU through the backplane. Up to two references at
a time may be accepted.

provide primary to secondary switchover (auto-recovery is provided)

prevent chatter

provide error burst detection and correction, holdover, and free running
capabilities

comply with 2.0Mb CCITT specifications

communicate with software

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.