beautypg.com

Nt8d15 e and m trunk card – Nortel Networks 1000 User Manual

Page 92

background image

92

Option settings

Table 31
NT8D14 vintages BA/BB trunk types-termination impedance and balance network (cont’d.)

Balance network for loop lengths (Note 2)

Trunk types

Terminating
impedance
(Note 1)

Zero–915 m

(zero–3000 ft)

915–1524 m

(3000–5000 ft)

> 1524 m

(> 5000 ft)

DID (loop ˇ

S 600

ohms)

600 or 900 ohms

600 ohms

N/A

3COM2

RAN: continuous
operation mode

600 or 900 ohms

600 or 900 ohms

N/A

N/A

Paging

600 ohms

600 ohms

N/A

N/A

Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and should
match the nominal impedance of the connecting equipment.

Note 2: The balance network of each trunk unit is software selectable between resistive 600 or 900
ohms or 3COM and is jumper selectable between 3COM1 and 3COM2.

Table 32
NT8D14 vintages BA/BB cable loop resistance and loss

Cable loop resistance (ohms)

Cable loop loss (dB)
(non-loaded at 1kHz)

Cable length

22 AWG

24 AWG

26 AWG

22 AWG

24 AWG

26 AWG

915 m (3000 ft)

97

155

251

0.9

1.2

1.5

1524 m (5000 ft)

162

260

417

1.6

2.0

2.5

2225 m (7300 ft)

236

378

609

2.3

3.0

3.7

3566 m (11700 ft)

379

607

977

3.7

4.8

6.0

5639 m (18500 ft)

600

960

1544

5.9

7.6

9.4

NT8D15 E and M Trunk card

Table 33
NT8D15 E and M Trunk card

Mode of operation (Note 2)

2-wire trunk

4-wire trunk

DX tip & ring pair

Jumper
(Note 1)

Type I

Paging

Type I

Type II

M—rcv
M—xmt

E—rcv
M—xmt

J1.X

off

off

off

off

Pins 1–2

Pins 2–3

J2.X

on

on
(Note 3)

on

on

off

off

J3.X

off

off

off

off

(Note 4)

(Note 4)

J4.X

off

off

off

off

Pins 2–3

Pins 1–2

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.