Nt8d15 e and m trunk card – Nortel Networks 1000 User Manual
Page 92
92
Option settings
Table 31
NT8D14 vintages BA/BB trunk types-termination impedance and balance network (cont’d.)
Balance network for loop lengths (Note 2)
Trunk types
Terminating
impedance
(Note 1)
Zero–915 m
(zero–3000 ft)
915–1524 m
(3000–5000 ft)
> 1524 m
(> 5000 ft)
DID (loop ˇ
S 600
ohms)
600 or 900 ohms
600 ohms
N/A
3COM2
RAN: continuous
operation mode
600 or 900 ohms
600 or 900 ohms
N/A
N/A
Paging
600 ohms
600 ohms
N/A
N/A
Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and should
match the nominal impedance of the connecting equipment.
Note 2: The balance network of each trunk unit is software selectable between resistive 600 or 900
ohms or 3COM and is jumper selectable between 3COM1 and 3COM2.
Table 32
NT8D14 vintages BA/BB cable loop resistance and loss
Cable loop resistance (ohms)
Cable loop loss (dB)
(non-loaded at 1kHz)
Cable length
22 AWG
24 AWG
26 AWG
22 AWG
24 AWG
26 AWG
915 m (3000 ft)
97
155
251
0.9
1.2
1.5
1524 m (5000 ft)
162
260
417
1.6
2.0
2.5
2225 m (7300 ft)
236
378
609
2.3
3.0
3.7
3566 m (11700 ft)
379
607
977
3.7
4.8
6.0
5639 m (18500 ft)
600
960
1544
5.9
7.6
9.4
NT8D15 E and M Trunk card
Table 33
NT8D15 E and M Trunk card
Mode of operation (Note 2)
2-wire trunk
4-wire trunk
DX tip & ring pair
Jumper
(Note 1)
Type I
Paging
Type I
Type II
M—rcv
M—xmt
E—rcv
M—xmt
J1.X
off
off
off
off
Pins 1–2
Pins 2–3
J2.X
on
on
(Note 3)
on
on
off
off
J3.X
off
off
off
off
(Note 4)
(Note 4)
J4.X
off
off
off
off
Pins 2–3
Pins 1–2
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.