NT8D14 Universal Trunk card
The jumper strap settings must be changed, as shown in
"Jumper strap settings - extended range (NT8D14BA, NT8D14BB,
NT8D14BB)" (page 608)
, for the following:
•
For CO/FX/WATS or TIE trunk loops exceeding 1524 meters (5000 ft.)
•
DID trunks exceeding a loop resistance of 600 ohms
•
RAN trunks operating in pulse start or level start modes
shows jumper locations on
the universal trunk card (vintage BA).
For most applications, the jumper strap settings remain set to the standard
configuration as shipped from the factory. See
settings - factory standard (NT8D14BA, NT8D14BB)" (page 614)
The jumper strap settings must be changed, as shown in
"Jumper strap settings - extended range (NT8D14BA, NT8D14BB,
NT8D14BB Release 10 and up)" (page 615)
, for the following:
•
For CO/FX/WATS or TIE trunk loops exceeding 1524 meters (5000 ft.)
•
DID trunks exceeding a loop resistance of 600 ohms
•
RAN trunks operating in pulse start or level start modes
shows jumper locations on
the universal trunk card (vintage BA).
Note:
Refer to Circuit Card: Description and Installation (NN43001-311)
for vintage AA jumper strap settings.