Functional description
663
the four units to configure trunk and signaling type. The remaining three
messages are sent per card to select the make/break ratio and the A-Law
and µ-Law modes.
The signaling and control circuits on the card perform the following
functions:
•
provide interface between the card and the system CPU
—
transmit PCM signals from each of the four units to one DS-30X
timeslot in A10 format (ready to send/clear to send—flow control,
handshake format)
—
transmit and receive signaling messages over a DS-30X signaling
channel in A10 format
•
decode received messages to set configuration and activate/deactivate
interface relays for PCM loopback diagnostic purposes
•
decode outpulsing messages (one per digit) from the CPU to drive
outpulsing relays at 20 pps, 10 pps1 (primary), or 10 pps2 (secondary)
•
monitor signals from the trunk interface and generate a message when
required for each state change
•
control disabling and enabling of unit or card
•
control of A-Law and µ-Law operation modes
•
control of transmission pad settings
The signaling and control portion of the E and M Trunk card works with the
system CPU to operate the card hardware. The card receives messages
from the CPU over a signaling channel in the DS-30X loop and returns
status information to the CPU over the same channel. The signaling and
control portion of the card provides analog loop terminations that establish,
supervise, and take down call connections.
Configuration information for the E and M trunk card is downloaded from
the CPU at power-up and by command from maintenance programs.
Configuration messages are sent. One message is sent to configure trunk
and signaling type. The other messages are sent to each card to select
the make/break ratio and the A-Law and Mu-Law modes.
The signaling and control circuits on the card perform the following
functions:
•
provide an interface between the card and the system CPU
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.