beautypg.com

Trunk data block – Nortel Networks 1000 User Manual

Page 910

background image

910

NTCK16 Generic Central Office Trunk cards

Table 389
LD 16 - Route Data Block for NTCK16AX.

Prompt

Response

Description

REQ:

NEW

Define a new unit

TYPE:

COT

Define a new Route Data Block

CUST

xx

Customer number as defined in LD 15.

ROUT

Route number

0-511

Range for Large System, Call Server 1000E,
and Media Gateway 1000E

0-127

Range for Small System, CS 1000E system,
Media Gateway 1000B, and
Media Gateway 1000T

TKTP

COT

Define trunk type as Central Office

ICOG

IAO

Incoming and Outgoing trunk

CNTL

YES

Change a trunk timer

TIMER

RGV 256

Set Ring Validation Timer to 128 ms.

MR

(NO) PPM XLD

PPM is off, buffered, or unbuffered on this route.

Trunk Data Block

Respond to the prompts in LD 14 as shown:

Table 390
LD 14 - Trunk Data Block for NTCK16AX.

Prompt

Response

Description

REQ:

NEW

Define a new trunk unit

TYPE:

COT

Central Office Trunk

TN

Terminal Number

l s c u

Format for Large System, Call Server
1000E, and Media Gateway 1000E,
where l = loop, s = shelf, c = card, u
= unit

XTRK
(See note on

"page 803"

(page 911)

.)

XCOT

Type is IPE COT

CDEN

(8D)

Card density is 8D (default)

SIGL

LOP

Loop start signaling

PPID
(See

"page 803" (page 911)

.)

Xx

04 Ireland/Turkey 12 KHz
03 Turkey 16 KHz

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.